MDAC - BETSA® - All for very high pressure experiments

Go to content

MDAC

Membrane Diamond Anvil Cell
        These Membrane Diamond Anvil Cell are aimed
at performing high pressure experiments at a large range of temperatures.


Pressure range : 0 to 3 Mbar (depending on the culet size of the diamonds)
Temperature range :
- 10 K to 450 K. Standard version
- RT to 1000 K. High temperature version
Accessible electromagnetic spectrum :
Visible, X rays, Raman and infrared (with specific diamonds)
Materials :
Maraging Steels & Tungsten Carbide (Standard) OR
Super Alloys & Super hard seat (High Temp.).
Sizes :
Height 32mm max (1.26”), Diameter 50mm (1.97”).
Weight :
125 g (0.288 lbs).
All these DACs & MDACs are
Designed, Manufactured and Produced by

BETSA® Company

Here is the BETSA® cells family. It may be possible to adapt any of these for your specific needs.
Very high pressure
Powder diffraction
Single cristal
Very high temperature [THT]
Brillouin spectroscopy [XBC]
Biologie


Radial diffraction
Pneumatic DAC
Amagnetic
-
MDAC Very High Pressure
These MDAC are aimed at performing very high pressure
experiments at a large range of temperatures.

Pressure range :
0 to 2 Mbar (depending on the culet size of the diamonds)
Temperature range :
10 K to 450 K or RT to 450 K.
Optical access to sample :
Full angle apertures 40°/40°
MDAC Powder diffraction
These MDAC are aimed at performing high pressure
experiments at a large range of temperatures.

Pressure range : 0 to 1.5 Mbar (depending on the culet size of the diamonds)
Temperature range : 10 K to 450 K or RT to 450 K.
Optical access to sample : Full angle apertures 60°/40°
MDAC Single crystal
These MDAC are aimed at performing high pressure
experiments at a large range of temperatures.

Pressure range : 0 to 1.5 Mbar (depending on the culet size of the diamonds)
Temperature range : 10 K to 450 K or RT to 450 K.
Optical access to sample : Full angle aperture 60°/60°.
MDAC Very high temperature
These MDAC are aimed at performing very high Temperature
experiments at Medium-High Pressure.

Pressure range : 0 to 1 Mbar (depending on the culet size of the diamonds).
Temperature range : Room temperature to 1000 K.
Optical access to sample : Full angle apertures 40° to 76°max/40° to 76°max
MDAC Brillouin spectroscopy
These MDAC are aimed at performing high Temperature
experiments at Medium-High Pressure

Pressure range : 0 to 1 Mbar (depending on the culet size of the diamonds)
Temperature range : Room temperature to 1000 K.
Optical access to sample : Full angle apertures 76°/76°/ Full angle apertures 135° Brewster
MDAC Biologie

These MDAC are aimed at performing at Medium Pressure experiments

Pressure range : 0 to 0,5 Mbar (depending on the culet size of the diamonds)
Temperature range : Room temperature to 450 K.
Optical access to sample : Full angle apertures 100°/100°
MDAC Radial diffraction
These MDAC are aimed at performing at Medium-High Pressure experiments.

Pressure range : 0 to 1 Mbar (depending on the culet size of the diamonds)
Temperature range : 10 K to 450 K.
Optical access to sample : Full angle apertures 76°/76°
Radial angle apertures 4x 70°/20°
PDAC Biologie pneumatic
Macromolecular crystallography at high pressure

A new pneumatic diamond anvil cell has been constructed, generating continuous pressure and temperature variations in the range 0–2.5 GPa .
The cell is designed mainly for high-pressure macromolecular crystallography and should facilitate pressure and temperature annealing of the sample.
Pressure range : 0 to 0,25 Mbar (depending on the culet size of the diamonds) .
Temperature range : Room temperature to 120°C. (Optional External heat ing 200°C.).
Optical access to sample : Full angle apertures 100°/100°. Working distance ³ 10,3mm (0.41”)
MDAC Amagnetic
Here is the BETSA® cells Adapted for Amagnetic experiments. It may be possible to adapt different options of these for your specific needs.

Radial diffraction and Amagnetic
Copyright © 2017 BETSA®. All Rights Reserved.
BETSA® is a world-leading brand for products and services in the area of the very high pressure experiments.
BETSA®
Z-I, 6 Bis,
Rue de la Commune de Paris
F 77370 NANGIS FRANCE
Back to content